Monitor adapters (zeroconf, enet, usb and w1) don't have the reset routine, causing null pointer dereference in BUS_reset function. This patch has been submitted upstream: https://sourceforge.net/p/owfs/bugs/67/ Signed-off-by: Marcin Jurkowski <marcin1j@gmail.com>
13 lines
425 B
Diff
13 lines
425 B
Diff
--- a/module/owlib/src/c/ow_reset.c
|
|
+++ b/module/owlib/src/c/ow_reset.c
|
|
@@ -21,6 +21,10 @@ RESET_TYPE BUS_reset(const struct parsed
|
|
struct connection_in * in = pn->selected_connection ;
|
|
STAT_ADD1_BUS(e_bus_resets, in);
|
|
|
|
+ if ( in->iroutines.reset == NO_RESET_ROUTINE ) {
|
|
+ return BUS_RESET_OK;
|
|
+ }
|
|
+
|
|
switch ( (in->iroutines.reset) (pn) ) {
|
|
case BUS_RESET_OK:
|
|
in->reconnect_state = reconnect_ok; // Flag as good!
|