diff --git a/net/modemmanager/Makefile b/net/modemmanager/Makefile index 3c021b44d..aa141ad73 100644 --- a/net/modemmanager/Makefile +++ b/net/modemmanager/Makefile @@ -9,7 +9,7 @@ include $(TOPDIR)/rules.mk PKG_NAME:=modemmanager PKG_SOURCE_VERSION:=1.20.6 -PKG_RELEASE:=3 +PKG_RELEASE:=4 PKG_SOURCE_PROTO:=git PKG_SOURCE_URL:=https://gitlab.freedesktop.org/mobile-broadband/ModemManager.git diff --git a/net/modemmanager/README.md b/net/modemmanager/README.md index c9d880ea4..e79b100c9 100644 --- a/net/modemmanager/README.md +++ b/net/modemmanager/README.md @@ -22,6 +22,7 @@ Once installed, you can configure the 2G/3G/4G modem connections directly in option password 'vodafone' option pincode '7423' option iptype 'ipv4' + option plmn '214001' option lowpower '1' option signalrate '30' @@ -36,5 +37,7 @@ allowing all protocols. The 'iptype' option supports any of these values: 'ipv4', 'ipv6' or 'ipv4v6'. It will default to 'ipv4' if not given. +The 'plmn' option allows to set the network operator MCCMNC. + The 'signalrate' option set's the signal refresh rate (in seconds) for the device. You can call signal info with command: mmcli -m 0 --signal-get diff --git a/net/modemmanager/files/modemmanager.proto b/net/modemmanager/files/modemmanager.proto index 2a61f5178..239148798 100755 --- a/net/modemmanager/files/modemmanager.proto +++ b/net/modemmanager/files/modemmanager.proto @@ -343,6 +343,7 @@ proto_modemmanager_init_config() { proto_config_add_string password proto_config_add_string pincode proto_config_add_string iptype + proto_config_add_string plmn proto_config_add_int signalrate proto_config_add_boolean lowpower proto_config_add_defaults @@ -355,11 +356,11 @@ proto_modemmanager_setup() { local bearermethod_ipv4 bearermethod_ipv6 auth cliauth local operatorname operatorid registration accesstech signalquality - local device apn allowedauth username password pincode iptype metric signalrate + local device apn allowedauth username password pincode iptype plmn metric signalrate local address prefix gateway mtu dns1 dns2 - json_get_vars device apn allowedauth username password pincode iptype metric signalrate + json_get_vars device apn allowedauth username password pincode iptype plmn metric signalrate # validate sysfs path given in config [ -n "${device}" ] || { @@ -392,7 +393,7 @@ proto_modemmanager_setup() { echo "starting connection with apn '${apn}'..." proto_notify_error "${interface}" MM_CONNECT_IN_PROGRESS - connectargs="apn=${apn}${iptype:+,ip-type=${iptype}}${cliauth:+,allowed-auth=${cliauth}}${username:+,user=${username}}${password:+,password=${password}}${pincode:+,pin=${pincode}}" + connectargs="apn=${apn}${iptype:+,ip-type=${iptype}}${plmn:+,operator-id=${plmn}}${cliauth:+,allowed-auth=${cliauth}}${username:+,user=${username}}${password:+,password=${password}}${pincode:+,pin=${pincode}}" mmcli --modem="${device}" --timeout 120 --simple-connect="${connectargs}" || { proto_notify_error "${interface}" MM_CONNECT_FAILED proto_block_restart "${interface}"