Merge pull request #7638 from cshoredaniel/pr-nut-backport
[18.06] nut: Backport fixes from master
This commit is contained in:
commit
c95a1d3da8
7 changed files with 395 additions and 165 deletions
|
@ -9,7 +9,7 @@ include $(TOPDIR)/rules.mk
|
|||
|
||||
PKG_NAME:=nut
|
||||
PKG_VERSION:=2.7.4
|
||||
PKG_RELEASE:=7
|
||||
PKG_RELEASE:=8
|
||||
|
||||
PKG_SOURCE:=$(PKG_NAME)-$(PKG_VERSION).tar.gz
|
||||
PKG_SOURCE_URL:=http://www.networkupstools.org/source/2.7/
|
||||
|
@ -63,22 +63,22 @@ define Package/nut/install
|
|||
endef
|
||||
|
||||
define Package/nut-server/install
|
||||
# Server portion
|
||||
$(INSTALL_DIR) $(1)/etc/nut
|
||||
$(INSTALL_DIR) $(1)/usr/sbin
|
||||
$(INSTALL_DIR) $(1)/etc/init.d
|
||||
$(INSTALL_DIR) $(1)/usr/share/nut
|
||||
$(INSTALL_DIR) $(1)/etc/init.d
|
||||
$(INSTALL_BIN) ./files/nut-server.init $(1)/etc/init.d/nut-server
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/upsd $(1)/usr/sbin
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/upsdrvctl $(1)/usr/sbin
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/share/nut/cmdvartab $(1)/usr/share/nut/
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/share/nut/driver.list $(1)/usr/share/nut/
|
||||
$(INSTALL_DIR) $(1)/etc/config
|
||||
$(INSTALL_CONF) ./files/nut_server $(1)/etc/config/nut_server
|
||||
ln -sf /var/etc/nut/nut.conf $(1)/etc/nut/nut.conf
|
||||
ln -sf /var/etc/nut/ups.conf $(1)/etc/nut/ups.conf
|
||||
ln -sf /var/etc/nut/upsd.users $(1)/etc/nut/upsd.users
|
||||
ln -sf /var/etc/nut/upsd.conf $(1)/etc/nut/upsd.conf
|
||||
# Driver common portion
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/upsdrvctl $(1)/usr/sbin
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/share/nut/driver.list $(1)/usr/share/nut/
|
||||
ln -sf /var/etc/nut/ups.conf $(1)/etc/nut/ups.conf
|
||||
endef
|
||||
|
||||
define Package/nut-common
|
||||
|
@ -96,6 +96,10 @@ $(call Package/nut/description/Default)
|
|||
This package contains the common files.
|
||||
endef
|
||||
|
||||
define Package/nut-common/conffiles
|
||||
/etc/nut/nut.conf
|
||||
endef
|
||||
|
||||
define Package/nut-common/install
|
||||
$(INSTALL_DIR) $(1)/etc/nut
|
||||
$(INSTALL_DIR) $(1)/usr/lib
|
||||
|
@ -107,6 +111,7 @@ define Package/nut-server
|
|||
$(call Package/nut/Default)
|
||||
TITLE+= (server)
|
||||
DEPENDS:=nut +nut-common
|
||||
USERID:=nut=113:nut=113
|
||||
endef
|
||||
|
||||
define Package/nut-server/description
|
||||
|
@ -120,6 +125,9 @@ endef
|
|||
|
||||
define Package/nut-server/conffiles
|
||||
/etc/config/nut_server
|
||||
/etc/nut/upsd.conf
|
||||
/etc/nut/upsd.users
|
||||
/etc/nut/ups.conf
|
||||
endef
|
||||
|
||||
define Package/nut-upsmon
|
||||
|
@ -141,6 +149,7 @@ endef
|
|||
|
||||
define Package/nut-upsmon/conffiles
|
||||
/etc/config/nut_monitor
|
||||
/etc/nut/upsmon.conf
|
||||
endef
|
||||
|
||||
define Package/nut-upsmon/install
|
||||
|
@ -149,6 +158,7 @@ define Package/nut-upsmon/install
|
|||
$(INSTALL_DIR) $(1)/etc/init.d
|
||||
$(INSTALL_BIN) ./files/nut-monitor.init $(1)/etc/init.d/nut-monitor
|
||||
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/upsmon $(1)/usr/sbin/
|
||||
$(INSTALL_BIN) ./files/nutshutdown $(1)/usr/sbin/nutshutdown
|
||||
$(INSTALL_DIR) $(1)/etc/config
|
||||
$(INSTALL_CONF) ./files/nut_monitor $(1)/etc/config/nut_monitor
|
||||
ln -sf /var/etc/nut/upsmon.conf $(1)/etc/nut/upsmon.conf
|
||||
|
@ -342,7 +352,7 @@ define DriverPackage
|
|||
define Package/nut-driver-$(2)
|
||||
$(call Package/nut/Default)
|
||||
TITLE:=$(2) (NUT $(1) driver)
|
||||
DEPENDS:=nut +nut-common
|
||||
DEPENDS:=nut +nut-server
|
||||
$(if $(filter $(1),snmp),DEPENDS+= @NUT_DRIVER_SNMP)
|
||||
$(if $(filter $(1),usb),DEPENDS+= @NUT_DRIVER_USB)
|
||||
$(if $(filter $(1),serial),DEPENDS+= @NUT_DRIVER_SERIAL)
|
||||
|
|
|
@ -25,7 +25,7 @@ nut_upscgi_add() {
|
|||
system="$system:$port";
|
||||
fi
|
||||
config_get displayname "$cfg" displayname
|
||||
echo "MONITOR $system \"$displayname\"" >> $UPSCGI_C
|
||||
echo "MONITOR $system \"$displayname\"" >> "$UPSCGI_C"
|
||||
}
|
||||
|
||||
start() {
|
||||
|
|
|
@ -1,61 +1,60 @@
|
|||
#!/bin/sh /etc/rc.common
|
||||
|
||||
START=60
|
||||
START=51
|
||||
USE_PROCD=1
|
||||
UPSMON_C=/var/etc/nut/upsmon.conf
|
||||
|
||||
nut_upsmon_conf() {
|
||||
local cfg="$1"
|
||||
|
||||
echo "# Config file automatically generated from UCI config" > $UPSMON_C
|
||||
echo "# Config file automatically generated from UCI config" > "$UPSMON_C"
|
||||
|
||||
config_get runas "$cfg" runas "nut"
|
||||
[ -n "$runas" ] && echo "RUN_AS_USER $runas" >> $UPSMON_C
|
||||
|
||||
config_get val "$cfg" minsupplies 1
|
||||
echo "MINSUPPLIES $val" >> $UPSMON_C
|
||||
echo "MINSUPPLIES $val" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" shutdowncmd "/sbin/halt"
|
||||
echo "SHUTDOWNCMD \"$val\"" >> $UPSMON_C
|
||||
config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown"
|
||||
echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" notifycmd
|
||||
[ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" pollfreq 5
|
||||
echo "POLLFREQ $val" >> $UPSMON_C
|
||||
echo "POLLFREQ $val" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" pollfreqalert 5
|
||||
echo "POLLFREQALERT $val" >> $UPSMON_C
|
||||
echo "POLLFREQALERT $val" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" hostsync 15
|
||||
echo "HOSTSYNC $val" >> $UPSMON_C
|
||||
echo "HOSTSYNC $val" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" deadtime 15
|
||||
echo "DEADTIME $val" >> $UPSMON_C
|
||||
echo "DEADTIME $val" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" powerdownflag /var/run/killpower
|
||||
echo "POWERDOWNFLAG $val" >> $UPSMON_C
|
||||
echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" onlinemsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" onbattmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" lowbattmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" fsdmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" commokmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" commbadmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" shutdownmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" replbattmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" nocommmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C"
|
||||
config_get val "$cfg" noparentmsg
|
||||
[ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> $UPSMON_C
|
||||
[ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C"
|
||||
|
||||
notifylist() {
|
||||
local value="$1"
|
||||
|
@ -85,34 +84,36 @@ nut_upsmon_conf() {
|
|||
val=""
|
||||
config_list_foreach "$cfg" defaultnotify notifylist
|
||||
default="$optval"
|
||||
echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> $UPSMON_C
|
||||
echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> "$UPSMON_C"
|
||||
echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" rbwarntime 43200
|
||||
echo "RBWARNTIME $val" >> $UPSMON_C
|
||||
echo "RBWARNTIME $val" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" nocommwarntime 300
|
||||
echo "NOCOMMWARNTIME $val" >> $UPSMON_C
|
||||
echo "NOCOMMWARNTIME $val" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" finaldelay 5
|
||||
echo "FINALDELAY $val" >> $UPSMON_C
|
||||
echo "FINALDELAY $val" >> "$UPSMON_C"
|
||||
|
||||
config_get val "$cfg" certpath
|
||||
if [ -n "$val" ]; then echo "CERTPATH $val" >> $UPSMON_C; fi
|
||||
if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi
|
||||
|
||||
config_get_bool val "$cfg" certverify 0
|
||||
if [ -n "$val" ]; then echo "CERTVERIFY $val" >> $UPSMON_C; fi
|
||||
if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi
|
||||
|
||||
config_get_bool val "$cfg" forcessl 0
|
||||
if [ -n "$val" ]; then echo "FORCESSL $val" >> $UPSMON_C; fi
|
||||
if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi
|
||||
|
||||
havemon=1
|
||||
}
|
||||
|
||||
nut_upsmon_add() {
|
||||
|
@ -126,12 +127,6 @@ nut_upsmon_add() {
|
|||
local password
|
||||
local system
|
||||
|
||||
# if UPSMON_C is a symlink we're only doing generated config
|
||||
[ -L $UPSMON_C ] && {
|
||||
rm -f $UPSMON_C
|
||||
nut_upsmon_conf ""
|
||||
}
|
||||
|
||||
config_get upsname "$cfg" upsname
|
||||
config_get hostname "$cfg" hostname localhost
|
||||
config_get port "$cfg" port
|
||||
|
@ -142,40 +137,56 @@ nut_upsmon_add() {
|
|||
if [ -n "$port" ]; then
|
||||
system="$system:$port";
|
||||
fi
|
||||
echo "MONITOR $system $powervalue $username $password $type" >> $UPSMON_C
|
||||
echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C"
|
||||
|
||||
havems=1
|
||||
}
|
||||
|
||||
start_service() {
|
||||
mkdir -p "$(dirname "$UPSMON_C")"
|
||||
chmod 750 "$(dirname "$UPSMON_C")"
|
||||
build_config() {
|
||||
local runas
|
||||
mkdir -m 0750 -p "$(dirname "$UPSMON_C")"
|
||||
|
||||
config_load nut_monitor
|
||||
|
||||
config_foreach nut_upsmon_conf upsmon
|
||||
config_foreach nut_upsmon_add master master
|
||||
config_foreach nut_upsmon_add slave slave
|
||||
|
||||
[ -z "$(cat /var/etc/nut/nut.conf)" ] && echo "MODE=netclient" >>/var/etc/nut/nut.conf
|
||||
|
||||
chmod 640 $UPSMON_C
|
||||
chmod 640 /var/etc/nut/nut.conf
|
||||
|
||||
chown ${runas:-root}:$(id -gn ${runas:-root}) /var/etc/nut
|
||||
chown ${runas:-root}:$(id -gn ${runas:-root}) /var/etc/nut/nut.conf
|
||||
chown ${runas:-root}:$(id -gn ${runas:-root}) $UPSMON_C
|
||||
|
||||
[ -d /var/run/nut ] || {
|
||||
mkdir -m 0750 -p /var/run/nut
|
||||
chown ${runas:-root}:$(id -gn ${runas:-root}) /var/run/nut
|
||||
[ ! -s "$(cat /var/etc/nut/nut.conf)" ] && {
|
||||
echo "MODE=netclient" >>/var/etc/nut/nut.conf
|
||||
chmod 640 /var/etc/nut/nut.conf
|
||||
chgrp $(id -gn ${runas:-root}) /var/etc/nut/nut.conf
|
||||
}
|
||||
|
||||
exec $DEBUG /usr/sbin/upsmon $UPSMON_OPTIONS
|
||||
[ -s "$UPSMON_C" ] && chmod 640 "$UPSMON_C"
|
||||
[ -s "$UPSMON_C" ] && chgrp $(id -gn ${runas:-root}) "$UPSMON_C"
|
||||
}
|
||||
|
||||
stop_service() {
|
||||
exec /usr/sbin/upsmon -c stop
|
||||
start_service() {
|
||||
local havemon havems
|
||||
build_config
|
||||
|
||||
[ "$havemon" != 1 ] && return
|
||||
[ "$havems" != 1 ] && return
|
||||
|
||||
procd_open_instance "upsmon"
|
||||
procd_set_param respawn
|
||||
procd_set_param stderr 0
|
||||
procd_set_param stdout 1
|
||||
procd_set_param command /usr/sbin/upsmon -D
|
||||
procd_close_instance
|
||||
}
|
||||
|
||||
reload_service() {
|
||||
exec /usr/sbin/upsmon -c reload
|
||||
if pgrep upsmon >/dev/null 2>/dev/null; then
|
||||
build_config
|
||||
/usr/sbin/upsmon -c reload
|
||||
else
|
||||
stop
|
||||
sleep 2
|
||||
start_service
|
||||
fi
|
||||
}
|
||||
|
||||
service_triggers() {
|
||||
procd_add_reload_trigger "nut_monitor"
|
||||
}
|
||||
|
|
|
@ -6,47 +6,79 @@
|
|||
#
|
||||
START=50
|
||||
|
||||
RUN_D=/var/run
|
||||
PID_F=$RUN_D/upsd.pid
|
||||
UPS_C=/var/etc/nut/ups.conf
|
||||
USERS_C=/var/etc/nut/upsd.users
|
||||
UPSD_C=/var/etc/nut/upsd.conf
|
||||
UPS_C=/var/etc/nut/ups.conf
|
||||
|
||||
USE_PROCD=1
|
||||
|
||||
get_write_driver_config() {
|
||||
local cfg="$1"
|
||||
local var="$2"
|
||||
local def="$3"
|
||||
local flag="$4"
|
||||
local val
|
||||
|
||||
[ -z "$flag" ] && {
|
||||
config_get val "$cfg" "$var" "$def"
|
||||
[ -n "$val" ] && [ "$val" != "0" ] && echo "$var = $val" >>"$UPS_C"
|
||||
}
|
||||
|
||||
[ -n "$flag" ] && {
|
||||
config_get_bool val "$cfg" "$var" "$def"
|
||||
[ "$val" = 1 ] && echo "$var" >>"$UPS_C"
|
||||
}
|
||||
}
|
||||
|
||||
upsd_statepath() {
|
||||
local cfg="$1"
|
||||
local statepath
|
||||
|
||||
config_get statepath "$cfg" statepath "/var/run/nut"
|
||||
STATEPATH="$statepath"
|
||||
}
|
||||
|
||||
upsd_runas() {
|
||||
local cfg="$1"
|
||||
local runas
|
||||
|
||||
[ -n "$RUNAS" ] && return
|
||||
|
||||
config_get runas "$cfg" runas "nut"
|
||||
RUNAS="$runas"
|
||||
}
|
||||
|
||||
listen_address() {
|
||||
local cfg="$1"
|
||||
|
||||
config_get address "$cfg" address "::1"
|
||||
config_get port "$cfg" port
|
||||
echo "LISTEN $address $port" >>$UPSD_C
|
||||
}
|
||||
|
||||
upsd_statepath() {
|
||||
local cfg="$1"
|
||||
config_get statepath "$cfg" statepath
|
||||
echo "LISTEN $address $port" >>"$UPSD_C"
|
||||
}
|
||||
|
||||
upsd_config() {
|
||||
local cfg="$1"
|
||||
local maxage maxconn certfile
|
||||
local maxage maxconn certfile runas statepath
|
||||
|
||||
# Note runas support requires you make sure USB device file is readable by
|
||||
# the runas user
|
||||
config_get runas "$cfg" runas
|
||||
config_get runas "$cfg" runas "nut"
|
||||
RUNAS="$runas"
|
||||
|
||||
config_get statepath "$cfg" statepath "/var/run/nut"
|
||||
STATEPATH="$statepath"
|
||||
|
||||
config_get maxage "$cfg" maxage
|
||||
[ -n "$maxage" ] && echo "MAXAGE $maxage" >>$UPSD_C
|
||||
[ -n "$maxage" ] && echo "MAXAGE $maxage" >>"$UPSD_C"
|
||||
|
||||
config_get statepath "$cfg" statepath
|
||||
[ -n "$statepath" ] && echo "STATEPATH $statepath" >>$UPSD_C
|
||||
[ -n "$statepath" ] && echo "STATEPATH $statepath" >>"$UPSD_C"
|
||||
|
||||
config_get maxconn "$cfg" maxconn
|
||||
[ -n "$maxconn" ] && echo "MAXCONN $maxconn" >>$UPSD_C
|
||||
[ -n "$maxconn" ] && echo "MAXCONN $maxconn" >>"$UPSD_C"
|
||||
|
||||
#NOTE: certs only apply to SSL-enabled version
|
||||
config_get certfile "$cfg" certfile
|
||||
[ -n "$certfile" ] && echo "CERTFILE $certfile" >>$UPSD_C
|
||||
[ -n "$certfile" ] && echo "CERTFILE $certfile" >>"$UPSD_C"
|
||||
}
|
||||
|
||||
nut_user_add() {
|
||||
|
@ -55,104 +87,241 @@ nut_user_add() {
|
|||
local val
|
||||
|
||||
config_get val "$cfg" username "$1"
|
||||
echo "[$val]" >> $USERS_C
|
||||
echo "[$val]" >> "$USERS_C"
|
||||
|
||||
config_get val "$cfg" password
|
||||
echo " password = $val" >> $USERS_C
|
||||
echo " password = $val" >> "$USERS_C"
|
||||
|
||||
config_get val "$cfg" actions
|
||||
for a in $val; do
|
||||
echo " actions = $a" >> $USERS_C
|
||||
echo " actions = $a" >> "$USERS_C"
|
||||
done
|
||||
|
||||
instcmd() {
|
||||
local val="$1"
|
||||
echo " instcmds = $val" >> $USERS_C
|
||||
echo " instcmds = $val" >> "$USERS_C"
|
||||
}
|
||||
|
||||
config_list_foreach "$cfg" instcmd instcmd
|
||||
|
||||
config_get val "$cfg" upsmon
|
||||
if [ -n "$val" ]; then
|
||||
echo " upsmon $val" >> $USERS_C
|
||||
echo " upsmon $val" >> "$USERS_C"
|
||||
fi
|
||||
}
|
||||
|
||||
build_server_config() {
|
||||
mkdir -m 0755 -p "$(dirname "$UPSD_C")"
|
||||
rm -f "$USERS_C"
|
||||
rm -f "$UPSD_C"
|
||||
rm -f /var/etc/nut/nut.conf
|
||||
|
||||
echo "# Config file automatically generated from UCI config" > "$USERS_C"
|
||||
echo "# Config file automatically generated from UCI config" > "$UPSD_C"
|
||||
|
||||
config_foreach nut_user_add user
|
||||
config_foreach listen_address listen_address
|
||||
config_foreach upsd_config upsd
|
||||
echo "MODE=netserver" >>/var/etc/nut/nut.conf
|
||||
|
||||
chmod 0640 "$USERS_C"
|
||||
chmod 0640 "$UPSD_C"
|
||||
chmod 0644 /var/etc/nut/nut.conf
|
||||
|
||||
[ -d "${STATEPATH}" ] || {
|
||||
mkdir -m 0750 -p "${STATEPATH}"
|
||||
}
|
||||
|
||||
if [ -n "$RUNAS" ]; then
|
||||
chown $RUNAS:$(id -gn $RUNAS) "${STATEPATH}"
|
||||
chgrp $(id -gn $RUNAS) "$USERS_C"
|
||||
chgrp $(id -gn $RUNAS) "$UPSD_C"
|
||||
fi
|
||||
haveserver=1
|
||||
}
|
||||
|
||||
build_driver_config() {
|
||||
local cfg="$1"
|
||||
|
||||
echo "[$cfg]" >>"$UPS_C"
|
||||
|
||||
get_write_driver_config "$cfg" driver "usbhid-ups"
|
||||
get_write_driver_config "$cfg" port "auto"
|
||||
get_write_driver_config "$cfg" sdorder
|
||||
get_write_driver_config "$cfg" desc
|
||||
get_write_driver_config "$cfg" nolock 0 1
|
||||
get_write_driver_config "$cfg" ignorelb 0 1
|
||||
get_write_driver_config "$cfg" mfr
|
||||
get_write_driver_config "$cfg" model
|
||||
get_write_driver_config "$cfg" serial
|
||||
get_write_driver_config "$cfg" sdtime
|
||||
get_write_driver_config "$cfg" offdelay
|
||||
get_write_driver_config "$cfg" ondelay
|
||||
get_write_driver_config "$cfg" pollfreq
|
||||
get_write_driver_config "$cfg" vendor
|
||||
get_write_driver_config "$cfg" product
|
||||
get_write_driver_config "$cfg" bus
|
||||
get_write_driver_config "$cfg" interruptonly 0 1
|
||||
get_write_driver_config "$cfg" interruptsize
|
||||
get_write_driver_config "$cfg" maxreport
|
||||
get_write_driver_config "$cfg" vendorid
|
||||
get_write_driver_config "$cfg" productid
|
||||
get_write_driver_config "$cfg" community
|
||||
get_write_driver_config "$cfg" snmp_version
|
||||
get_write_driver_config "$cfg" snmp_retries
|
||||
get_write_driver_config "$cfg" snmp_timeout
|
||||
get_write_driver_config "$cfg" notransferoids 0 1
|
||||
get_write_driver_config "$cfg" maxstartdelay
|
||||
get_write_driver_config "$cfg" retrydelay
|
||||
get_write_driver_config "$cfg" synchronous
|
||||
get_write_driver_config "$cfg" other
|
||||
get_write_driver_config "$cfg" otherflag
|
||||
|
||||
defoverride() {
|
||||
local overvar="$1"
|
||||
local defover="$2"
|
||||
local overtype="$(echo "$overvar" | tr '.' '_')"
|
||||
|
||||
config_get overval "${defover}_${overtype}" value
|
||||
[ -n "$overval" ] && echo "${defover}.${overvar} = $overval" >>"$UPS_C"
|
||||
}
|
||||
|
||||
config_list_foreach "$cfg" override defoverride override
|
||||
config_list_foreach "$cfg" default defoverride default
|
||||
|
||||
other() {
|
||||
local othervar="$1"
|
||||
local othervarflag="$2"
|
||||
|
||||
if [ "$othervarflag" = "otherflag" ]; then
|
||||
config_get_bool otherval "${othervarflag}_${overtype}" value
|
||||
[ "$otherval" = "1" ] && echo "${othervarflag}_${othervar}" >>"$UPS_C"
|
||||
else
|
||||
config_get otherval "${othervarflag}_${overtype}" value
|
||||
[ -n "$otherval" ] && echo "${othervarflag}_${othervar} = $otherval" >>"$UPS_C"
|
||||
fi
|
||||
}
|
||||
|
||||
config_list_foreach "$cfg" override defoverride override
|
||||
config_list_foreach "$cfg" default defoverride default
|
||||
config_list_foreach "$cfg" default other other
|
||||
config_list_foreach "$cfg" default other otherflag
|
||||
echo "" >>$UPS_C
|
||||
havedriver=1
|
||||
}
|
||||
|
||||
build_global_driver_config() {
|
||||
local cfg="$1"
|
||||
|
||||
# Global driver config
|
||||
get_write_driver_config "$cfg" chroot
|
||||
get_write_driver_config "$cfg" driverpath
|
||||
get_write_driver_config "$cfg" maxstartdelay
|
||||
get_write_driver_config "$cfg" maxretry
|
||||
get_write_driver_config "$cfg" retrydelay
|
||||
get_write_driver_config "$cfg" pollinterval
|
||||
get_write_driver_config "$cfg" synchronous
|
||||
config_get runas "$cfg" user "nut"
|
||||
RUNAS="$runas"
|
||||
upsd_runas
|
||||
|
||||
echo "" >>$UPS_C
|
||||
}
|
||||
|
||||
build_config() {
|
||||
local RUNAS=nut
|
||||
local STATEPATH=/var/run/nut
|
||||
|
||||
mkdir -m 0755 -p "$(dirname "$UPS_C")"
|
||||
rm -f "$UPS_C"
|
||||
echo "# Config file automatically generated from UCI config" > "$UPS_C"
|
||||
chmod 0640 "$UPS_C"
|
||||
|
||||
config_load nut_server
|
||||
config_foreach upsd_statepath upsd
|
||||
|
||||
config_foreach build_global_driver_config driver_global
|
||||
config_foreach build_driver_config driver
|
||||
[ -n "$RUNAS" ] && chgrp $(id -gn $RUNAS) "$UPS_C"
|
||||
|
||||
build_server_config
|
||||
}
|
||||
|
||||
start_driver_instance() {
|
||||
local cfg="$1"
|
||||
local requested="$2"
|
||||
local driver
|
||||
local STATEPATH=/var/run/nut
|
||||
local RUNAS=nut
|
||||
|
||||
[ "$havedriver" != 1 ] && return
|
||||
|
||||
# If wanting a specific instance, only start it
|
||||
[ "$requested" != "$cfg" ] && [ x"$requested" != x ] && return 0
|
||||
|
||||
mkdir -m 0755 -p "$(dirname "$UPS_C")"
|
||||
|
||||
[ ! -s "$UPS_C" ] && build_config
|
||||
|
||||
# Avoid hotplug inadvertenly restarting driver during
|
||||
# forced shutdown
|
||||
[ -f /var/run/killpower ] && return 0
|
||||
[ -d /var/run/nut ] && [ -f /var/run/nut/disable-hotplug ] && return 0
|
||||
|
||||
|
||||
config_foreach upsd_statepath upsd
|
||||
|
||||
if [ -n "$RUNAS" ]; then
|
||||
chown $RUNAS:$(id -gn $RUNAS) "${STATEPATH}"
|
||||
fi
|
||||
|
||||
config_get driver "$cfg" driver "usbhid-ups"
|
||||
procd_open_instance "$cfg"
|
||||
procd_set_param respawn
|
||||
procd_set_param stderr 0
|
||||
procd_set_param stdout 1
|
||||
procd_set_param command /lib/nut/${driver} -D -a "$cfg" ${RUNAS:+-u $RUNAS}
|
||||
procd_close_instance
|
||||
}
|
||||
|
||||
start_server_instance() {
|
||||
local RUNAS
|
||||
build_config
|
||||
|
||||
[ "$haveserver" != 1 ] && return
|
||||
|
||||
procd_open_instance "upsd"
|
||||
procd_set_param respawn
|
||||
procd_set_param stderr 0
|
||||
procd_set_param stdout 1
|
||||
procd_set_param command /usr/sbin/upsd -D ${RUNAS:+-u $RUNAS}
|
||||
procd_close_instance
|
||||
}
|
||||
|
||||
start_service() {
|
||||
local runas statepath
|
||||
local havedriver haveserver
|
||||
local STATEPATH=/var/run/nut
|
||||
|
||||
mkdir -p /var/etc/nut
|
||||
chmod -R 750 /var/etc/nut
|
||||
|
||||
rm -f $UPSD_C
|
||||
rm -f $USERS_C
|
||||
rm -f $UPSD_C
|
||||
rm -f /var/etc/nut/nut.conf
|
||||
|
||||
echo "# Config file automatically generated from UCI config" > $UPS_C
|
||||
echo "# Config file automatically generated from UCI config" > $USERS_C
|
||||
echo "# Config file automatically generated from UCI config" > $UPSD_C
|
||||
|
||||
local in_driver have_drivers
|
||||
config_cb() {
|
||||
if [ "$1" != "driver" ]; then
|
||||
in_driver=
|
||||
else
|
||||
echo "[$2]" >> $UPS_C
|
||||
in_driver=true
|
||||
have_drivers=true
|
||||
fi
|
||||
}
|
||||
option_cb() {
|
||||
if [ "$in_driver" = "true" ]; then
|
||||
echo " $1 = $2" >> $UPS_C
|
||||
fi
|
||||
}
|
||||
# Avoid hotplug inadvertenly restarting driver during
|
||||
# forced shutdown
|
||||
[ -f /var/run/killpower ] && return 0
|
||||
[ -f /var/run/nut/disable-hotplug ] && return 0
|
||||
|
||||
config_load nut_server
|
||||
|
||||
config_foreach nut_user_add user
|
||||
config_foreach upsd_config upsd
|
||||
config_foreach listen_address listen_address
|
||||
build_config
|
||||
config_foreach start_driver_instance driver "$@"
|
||||
|
||||
echo "MODE=netserver" >>/var/etc/nut/nut.conf
|
||||
|
||||
chmod 0640 $USERS_C
|
||||
chmod 0640 $UPS_C
|
||||
chmod 0640 $UPSD_C
|
||||
chmod 0640 /var/etc/nut/nut.conf
|
||||
[ -d "${statepath:-/var/run/nut}" ] || {
|
||||
mkdir -m 0750 -p "${statepath:-/var/run/nut}"
|
||||
chown $runas:$(id -gn $runas) "${statepath:-/var/run/nut}"
|
||||
}
|
||||
|
||||
if [ -n "$runas" ]; then
|
||||
chown -R $runas:$(id -gn $runas) /var/etc/nut
|
||||
fi
|
||||
|
||||
if [ "$have_drivers" = "true" ]; then
|
||||
$DEBUG /usr/sbin/upsd ${runas:+-u $runas} $OPTIONS
|
||||
$DEBUG /usr/sbin/upsdrvctl ${runas:+-u $runas} start
|
||||
fi
|
||||
}
|
||||
|
||||
|
||||
nut_driver_stop() {
|
||||
local cfg="$1"
|
||||
local driver
|
||||
|
||||
config_get driver "$cfg" driver
|
||||
|
||||
[ -r ${statepath:-/var/run/nut}/$driver-$cfg ] && /usr/sbin/upsdrvctl stop $cfg
|
||||
}
|
||||
|
||||
stop_service() {
|
||||
[ -r $PID_F ] && /usr/sbin/upsd -c stop
|
||||
config_load ups
|
||||
config_foreach upsd_statepath upsd
|
||||
config_foreach nut_driver_stop driver
|
||||
start_server_instance "upsd"
|
||||
}
|
||||
|
||||
reload_service() {
|
||||
upsd -c reload
|
||||
stop
|
||||
sleep 2
|
||||
local havedriver haveserver
|
||||
start
|
||||
}
|
||||
|
||||
service_triggers() {
|
||||
procd_add_reload_trigger "nut_server"
|
||||
}
|
||||
|
|
|
@ -1,14 +1,13 @@
|
|||
#config upsmon 'upsmon'
|
||||
# option runas run-as-user
|
||||
# option minsupplies 1
|
||||
# option shutdowncmd /sbin/halt
|
||||
# option shutdowncmd '/usr/sbin/nutshutdown'
|
||||
# option notifycmd /path/to/cmd
|
||||
# list defaultnotify SYSLOG
|
||||
# option pollfreq 5
|
||||
# option pollfreqalert 5
|
||||
# option hostsync 15
|
||||
# option deadtime 15
|
||||
# option powerdownflags /var/run/killpower
|
||||
# option onlinemsg "online message"
|
||||
# option onbattmsg "on battery message"
|
||||
# option lowbattmsg "low battery message"
|
||||
|
@ -51,4 +50,3 @@
|
|||
# option powervalue 1
|
||||
# option username upsuser
|
||||
# option password upspassword
|
||||
|
||||
|
|
|
@ -19,5 +19,6 @@
|
|||
# option maxage 15
|
||||
# option statepath /var/run/nut
|
||||
# option maxconn 1024
|
||||
# option runas nut
|
||||
# NB: certificates only apply to SSL-enabled version
|
||||
# option certfile /usr/local/etc/upsd.pem
|
||||
|
|
41
net/nut/files/nutshutdown
Executable file
41
net/nut/files/nutshutdown
Executable file
|
@ -0,0 +1,41 @@
|
|||
#!/bin/sh
|
||||
#
|
||||
# This is free software, licensed under the GNU General Public License v2.
|
||||
# See /LICENSE for more information.
|
||||
#
|
||||
|
||||
. /lib/functions.sh
|
||||
|
||||
mount -o remount,ro /overlay /overlay
|
||||
mount -o remount,ro / /
|
||||
|
||||
stop_instance() {
|
||||
/etc/init.d/nut-server stop "$1"
|
||||
}
|
||||
|
||||
shutdown_instance() {
|
||||
local cfg="$1"
|
||||
config_get driver "$cfg" driver "usbhid-ups"
|
||||
/lib/nut/${driver} -a "$cfg" -k
|
||||
}
|
||||
|
||||
[ -f /var/run/killpower ] && {
|
||||
[ -f /etc/config/nut_server ] && {
|
||||
config_load nut_server
|
||||
|
||||
# Can't FSD unless drivers are stopped
|
||||
config_foreach stop_instance driver
|
||||
# Driver will wait 'offdelay' before shutting down
|
||||
config_foreach shutdown_instance driver
|
||||
# So this can happen
|
||||
poweroff
|
||||
# And just in case
|
||||
sleep 120
|
||||
# Uh-oh failed to poweroff UPS
|
||||
reboot -f
|
||||
} || {
|
||||
poweroff
|
||||
}
|
||||
} || {
|
||||
poweroff
|
||||
}
|
Loading…
Reference in a new issue