luci/modules/luci-mod-admin-full/luasrc/view/admin_system/flashops.htm
Jo-Philipp Wich 94ab57f48c luci-mod-admin-full: restructure and fix backup, restore and sysuprade (#517)
Do not use standard post security checking for actions that require file upload
since reading the token value will trigger parsing of the http message body
before the file upload handler has been set, which causes LuCI to buffer the
entire request body in memory.

In order to simplify the code and logic flow, split action_flashops() into
separate handlers for reset, backup, restore and sysupgrade.

Let the backup restore and sysupgrade handlers use the new test_post_security()
method in luci.dispatcher to perform token checking *after* setting the upload
handler.

Signed-off-by: Jo-Philipp Wich <jow@openwrt.org>
2015-10-22 08:48:06 +02:00

93 lines
4.1 KiB
HTML

<%#
Copyright 2008 Steven Barth <steven@midlink.org>
Copyright 2008-2015 Jo-Philipp Wich <jow@openwrt.org>
Licensed to the public under the Apache License 2.0.
-%>
<%+header%>
<h2 name="content"><%:Flash operations%></h2>
<ul class="cbi-tabmenu">
<li class="cbi-tab"><a href="#"><%:Actions%></a></li>
<li class="cbi-tab-disabled"><a href="<%=REQUEST_URI%>/backupfiles"><%:Configuration%></a></li>
</ul>
<fieldset class="cbi-section">
<fieldset class="cbi-section">
<legend><%:Backup / Restore%></legend>
<div class="cbi-section-descr"><%:Click "Generate archive" to download a tar archive of the current configuration files. To reset the firmware to its initial state, click "Perform reset" (only possible with squashfs images).%></div>
<div class="cbi-section-node">
<form class="inline" method="post" action="<%=url('admin/system/flashops/backup')%>">
<input type="hidden" name="token" value="<%=token%>" />
<div class="cbi-value<% if not reset_avail then %> cbi-value-last<% end %>">
<label class="cbi-value-title" for="image"><%:Download backup%>:</label>
<div class="cbi-value-field">
<input class="cbi-button cbi-button-apply" type="submit" name="backup" value="<%:Generate archive%>" />
</div>
</div>
</form>
<% if reset_avail then %>
<form class="inline" method="post" action="<%=url('admin/system/flashops/reset')%>">
<input type="hidden" name="token" value="<%=token%>" />
<div class="cbi-value cbi-value-last">
<label class="cbi-value-title"><%:Reset to defaults%>:</label>
<div class="cbi-value-field">
<input onclick="return confirm('<%:Really reset all changes?%>')" class="cbi-button cbi-button-reset" type="submit" name="reset" value="<%:Perform reset%>" />
</div>
</div>
</form>
<% end %>
</div>
<br />
<div class="cbi-section-descr"><%:To restore configuration files, you can upload a previously generated backup archive here.%></div>
<div class="cbi-section-node">
<form class="inline" method="post" action="<%=url('admin/system/flashops/restore')%>" enctype="multipart/form-data">
<div class="cbi-value cbi-value-last">
<label class="cbi-value-title" for="archive"><%:Restore backup%>:</label>
<div class="cbi-value-field">
<input type="hidden" name="token" value="<%=token%>" />
<input type="file" name="archive" id="archive" />
<input type="submit" class="cbi-button cbi-input-apply" name="restore" value="<%:Upload archive...%>" />
</div>
</div>
</form>
</div>
</fieldset>
<br />
<fieldset class="cbi-section">
<legend><%:Flash new firmware image%></legend>
<% if upgrade_avail then %>
<form method="post" action="<%=url('admin/system/flashops/sysupgrade')%>" enctype="multipart/form-data">
<input type="hidden" name="token" value="<%=token%>" />
<div class="cbi-section-descr"><%:Upload a sysupgrade-compatible image here to replace the running firmware. Check "Keep settings" to retain the current configuration (requires an OpenWrt compatible firmware image).%></div>
<div class="cbi-section-node">
<div class="cbi-value">
<label class="cbi-value-title" for="keep"><%:Keep settings%>:</label>
<div class="cbi-value-field">
<input type="checkbox" name="keep" id="keep" checked="checked" />
</div>
</div>
<div class="cbi-value cbi-value-last<% if image_invalid then %> cbi-value-error<% end %>">
<label class="cbi-value-title" for="image"><%:Image%>:</label>
<div class="cbi-value-field">
<input type="file" name="image" id="image" />
<input type="submit" class="cbi-button cbi-input-apply" value="<%:Flash image...%>" />
</div>
</div>
</div>
<% if image_invalid then %>
<div class="cbi-section-error"><%:The uploaded image file does not contain a supported format. Make sure that you choose the generic image format for your platform. %></div>
<% end %>
</form>
<% else %>
<div class="cbi-section-descr"><%:Sorry, there is no sysupgrade support present; a new firmware image must be flashed manually. Please refer to the OpenWrt wiki for device specific install instructions.%></div>
<% end %>
</fieldset>
</fieldset>
<%+footer%>