This change splits the graph into two graphs like in apcups and makes it so possible to see variations in AC Input/Output voltages. Battery charge and load are indepentent variables. This change also overlays them and display them as simply two lines. Battery temperature is also displayed as a line now, as an area under a temperature line makes no sense. Also removed some empty lines. Closes: #2417 Signed-off-by: Fabian Schmid-Michels <mail@wohnheimnetz-bielefeld.de> Signed-off-by: Florian Eckert <fe@dev.tdt.de>
130 lines
3.1 KiB
Lua
130 lines
3.1 KiB
Lua
-- Licensed to the public under the Apache License 2.0.
|
|
|
|
module("luci.statistics.rrdtool.definitions.nut",package.seeall)
|
|
|
|
function item()
|
|
return luci.i18n.translate("UPS")
|
|
end
|
|
|
|
function rrdargs( graph, plugin, plugin_instance, dtype )
|
|
|
|
local voltages_ac = {
|
|
title = "%H: AC voltages on UPS \"%pi\"",
|
|
vlabel = "V",
|
|
number_format = "%5.1lfV",
|
|
data = {
|
|
instances = {
|
|
voltage = { "input", "output" }
|
|
},
|
|
options = {
|
|
voltage_output = { color = "00e000", title = "Output voltage", noarea=true, overlay=true },
|
|
voltage_input = { color = "ffb000", title = "Input voltage", noarea=true, overlay=true }
|
|
}
|
|
}
|
|
}
|
|
|
|
local voltages_dc = {
|
|
title = "%H: Battery voltage on UPS \"%pi\"",
|
|
vlabel = "V",
|
|
number_format = "%5.1lfV",
|
|
data = {
|
|
instances = {
|
|
voltage = { "battery" }
|
|
},
|
|
options = {
|
|
voltage = { color = "0000ff", title = "Battery voltage", noarea=true, overlay=true }
|
|
}
|
|
}
|
|
}
|
|
|
|
local currents = {
|
|
title = "%H: Current on UPS \"%pi\"",
|
|
vlabel = "A",
|
|
number_format = "%5.3lfA",
|
|
data = {
|
|
instances = {
|
|
current = { "battery", "output" }
|
|
},
|
|
options = {
|
|
current_output = { color = "00e000", title = "Output current", noarea=true, overlay=true },
|
|
current_battery = { color = "0000ff", title = "Battery current", noarea=true, overlay=true }
|
|
}
|
|
}
|
|
}
|
|
|
|
local percentage = {
|
|
title = "%H: Battery charge/load on UPS \"%pi\"",
|
|
vlabel = "Percent",
|
|
y_min = "0",
|
|
y_max = "100",
|
|
number_format = "%5.1lf%%",
|
|
data = {
|
|
instances = {
|
|
percent = { "charge", "load" }
|
|
},
|
|
options = {
|
|
percent_charge = { color = "00ff00", title = "Charge level", noarea=true, overlay=true },
|
|
percent_load = { color = "ff0000", title = "Load", noarea=true, overlay=true }
|
|
}
|
|
}
|
|
}
|
|
|
|
-- Note: This is in ISO8859-1 for rrdtool. Welcome to the 20th century.
|
|
local temperature = {
|
|
title = "%H: Battery temperature on UPS \"%pi\"",
|
|
vlabel = "\176C",
|
|
number_format = "%5.1lf\176C",
|
|
data = {
|
|
instances = {
|
|
temperature = "battery"
|
|
},
|
|
options = {
|
|
temperature_battery = { color = "ffb000", title = "Battery temperature", noarea=true }
|
|
}
|
|
}
|
|
}
|
|
|
|
local timeleft = {
|
|
title = "%H: Time left on UPS \"%pi\"",
|
|
vlabel = "Minutes",
|
|
number_format = "%.1lfm",
|
|
data = {
|
|
instances = {
|
|
timeleft = { "battery" }
|
|
},
|
|
options = {
|
|
timeleft_battery = { color = "0000ff", title = "Time left", transform_rpn = "60,/", noarea=true }
|
|
}
|
|
}
|
|
}
|
|
|
|
local power = {
|
|
title = "%H: Power on UPS \"%pi\"",
|
|
vlabel = "Power",
|
|
number_format = "%5.1lf%%",
|
|
data = {
|
|
instances = {
|
|
power = { "ups" }
|
|
},
|
|
options = {
|
|
power_ups = { color = "00ff00", title = "Power level" }
|
|
}
|
|
}
|
|
}
|
|
|
|
local frequencies = {
|
|
title = "%H: Frequencies on UPS \"%pi\"",
|
|
vlabel = "Hz",
|
|
number_format = "%5.1lfHz",
|
|
data = {
|
|
instances = {
|
|
frequency = { "input", "output" }
|
|
},
|
|
options = {
|
|
frequency_output = { color = "00e000", title = "Output frequency", noarea=true, overlay=true },
|
|
frequency_input = { color = "ffb000", title = "Input frequency", noarea=true, overlay=true }
|
|
}
|
|
}
|
|
}
|
|
return { voltages_ac, voltages_dc, currents, percentage, temperature, timeleft, power, frequencies }
|
|
end
|