-- Copyright 2017-2018 Stan Grishin <stangri@melmac.net> -- Licensed to the public under the Apache License 2.0. module("luci.controller.advanced_reboot", package.seeall) local util = require "luci.util" local fs = require "nixio.fs" local sys = require "luci.sys" local http = require "luci.http" local dispatcher = require "luci.dispatcher" local i18n = require "luci.i18n" local ltemplate = require "luci.template" local ip = require "luci.ip" local http = require "luci.http" local sys = require "luci.sys" local dispatcher = require "luci.dispatcher" local uci = require "luci.model.uci".cursor() function is_alt_mountable(p1_mtd, p2_mtd) if p1_mtd:sub(1,3) == "mtd" and p2_mtd:sub(1,3) == "mtd" and fs.access("/usr/sbin/ubiattach") and fs.access("/usr/sbin/ubiblock") and fs.access("/bin/mount") then return true else return false end end function get_partition_os_info(op_ubi) local cp_info, ap_info if fs.access("/etc/os-release") then cp_info = util.trim(util.exec('. /etc/os-release && echo "$PRETTY_NAME"')) end alt_partition_unmount(op_ubi) alt_partition_mount(op_ubi) if fs.access("/alt/rom/etc/os-release") then ap_info = util.trim(util.exec('. /alt/rom/etc/os-release && echo "$PRETTY_NAME"')) end alt_partition_unmount(op_ubi) return cp_info, ap_info end function alt_partition_mount(op_ubi) local ubi_dev util.exec('for i in rom overlay firmware; do [ ! -d "$i" ] && mkdir -p "/alt/${i}"; done') ubi_dev = tostring(util.exec("ubiattach -m " .. tostring(op_ubi))) _, _, ubi_dev = ubi_dev:find("UBI device number (%d+)") if not ubi_dev then util.exec("ubidetach -m " .. tostring(op_ubi)) return end util.exec("ubiblock --create /dev/ubi" .. ubi_dev .. "_0") util.exec("mount -t squashfs -o ro /dev/ubiblock" .. ubi_dev .. "_0 /alt/rom") util.exec("mount -t ubifs /dev/ubi" .. ubi_dev .. "_1 /alt/overlay") -- util.exec("mount -t overlay overlay -o noatime,lowerdir=/alt/rom,upperdir=/alt/overlay/upper,workdir=/alt/overlay/work /alt/firmware") end function alt_partition_unmount(op_ubi) -- util.exec("[ -d /alt/firmware ] && umount /alt/firmware") util.exec("[ -d /alt/overlay ] && umount /alt/overlay") util.exec("[ -d /alt/rom ] && umount /alt/rom") for i = 0, 10 do if not fs.access("/sys/devices/virtual/ubi/ubi" .. tostring(i) .. "/mtd_num") then break end ubi_mtd = tonumber(util.trim(util.exec("cat /sys/devices/virtual/ubi/ubi" .. i .. "/mtd_num"))) if ubi_mtd and ubi_mtd == op_ubi then util.exec("ubiblock --remove /dev/ubi" .. tostring(i) .. "_0") util.exec("ubidetach -m " .. tostring(op_ubi)) util.exec('rm -rf /alt') end end end devices = { -- deviceName, boardName, part1MTD, part2MTD, offset, envVar1, envVar1Value1, envVar1Value2, envVar2, envVar2Value1, envVar2Value2 {"Linksys EA3500", "linksys-audi", "mtd3", "mtd5", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys E4200v2/EA4500", "linksys-viper", "mtd3", "mtd5", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys EA6350v3", "linksys-ea6350v3", "mtd10", "mtd12", 192, "boot_part", 1, 2}, {"Linksys EA8300", "linksys-ea8300", "mtd10", "mtd12", 192, "boot_part", 1, 2}, {"Linksys EA8500", "ea8500", "mtd13", "mtd15", 32, "boot_part", 1, 2}, -- {"Linksys EA9500", "linksys-panamera", "mtd3", "mtd6", 28, "boot_part", 1, 2}, {"Linksys WRT1200AC", "linksys-caiman", "mtd4", "mtd6", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT1900AC", "linksys-mamba", "mtd4", "mtd6", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT1900ACv2", "linksys-cobra", "mtd4", "mtd6", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT1900ACS", "linksys-shelby", "mtd4", "mtd6", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT3200ACM", "linksys-rango", "mtd5", "mtd7", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT32X", "linksys-venom", "mtd5", "mtd7", nil, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"ZyXEL NBG6817", "nbg6817", "mmcblk0p4", "mmcblk0p7", 32, nil, 255, 1} } -- local errorMessage, d -- local device_name, p1_mtd, p2_mtd, offset, bev1, bev1p1, bev1p2, bev2, bev2p1, bev2p2 romBoardName = util.trim(util.exec("cat /tmp/sysinfo/board_name")) for i=1, #devices do d = devices[i][2]:gsub('%p','') if romBoardName and romBoardName:gsub('%p',''):match(d) then device_name = devices[i][1] p1_mtd = devices[i][3] or nil p2_mtd = devices[i][4] or nil offset = devices[i][5] or nil bev1 = devices[i][6] or nil bev1p1 = tonumber(devices[i][7]) or nil bev1p2 = tonumber(devices[i][8]) or nil bev2 = devices[i][9] or nil bev2p1 = devices[i][10] or nil bev2p2 = devices[i][11] or nil if p1_mtd and offset then p1_label = util.trim(util.exec("dd if=/dev/" .. p1_mtd .. " bs=1 skip=" .. offset .. " count=128" .. " 2>/dev/null")) n, p1_version = p1_label:match('(Linux)-([%d|.]+)') end if p2_mtd and offset then p2_label = util.trim(util.exec("dd if=/dev/" .. p2_mtd .. " bs=1 skip=" .. offset .. " count=128" .. " 2>/dev/null")) n, p2_version = p2_label:match('(Linux)-([%d|.]+)') end if p1_label and p1_label:find("LEDE") then p1_os = "LEDE" end if p1_label and p1_label:find("OpenWrt") then p1_os = "OpenWrt" end if p1_label and p1_label:find("Linksys") then p1_os = "Linksys" end if p2_label and p2_label:find("LEDE") then p2_os = "LEDE" end if p2_label and p2_label:find("OpenWrt") then p2_os = "OpenWrt" end if p2_label and p2_label:find("Linksys") then p2_os = "Linksys" end if device_name == "ZyXEL NBG6817" then if not p1_os then p1_os = "ZyXEL" end if not p2_os then p2_os = "ZyXEL" end end if device_name == "Linksys WRT32X" then if not p1_os then p1_os = "Unknown/Compressed" end if not p2_os then p2_os = "Unknown/Compressed" end end if not p1_os then p1_os = "Unknown" end if not p2_os then p2_os = "Unknown" end if p1_os and p1_version then p1_os = p1_os .. " (Linux " .. p1_version .. ")" end if p2_os and p2_version then p2_os = p2_os .. " (Linux " .. p2_version .. ")" end if device_name == "ZyXEL NBG6817" then if not zyxelFlagPartition then zyxelFlagPartition = util.trim(util.exec(". /lib/functions.sh; find_mtd_part 0:DUAL_FLAG")) end if not zyxelFlagPartition then errorMessage = errorMessage or "" .. i18n.translate("Unable to find Dual Boot Flag Partition." .. " ") util.perror(i18n.translate("Unable to find Dual Boot Flag Partition.")) else current_partition = tonumber(util.exec("dd if=" .. zyxelFlagPartition .. " bs=1 count=1 2>/dev/null | hexdump -n 1 -e '1/1 \"%d\"'")) end else if fs.access("/usr/sbin/fw_printenv") and fs.access("/usr/sbin/fw_setenv") then current_partition = tonumber(util.trim(util.exec("fw_printenv -n " .. bev1))) end end other_partition = current_partition == bev1p2 and bev1p1 or bev1p2 if is_alt_mountable(p1_mtd, p2_mtd) then if current_partition == bev1p1 then op_ubi = tonumber(p2_mtd:sub(4)) + 1 else op_ubi = tonumber(p1_mtd:sub(4)) + 1 end local cp_info, ap_info = get_partition_os_info(op_ubi) if current_partition == bev1p1 then p1_os = cp_info or p1_os p2_os = ap_info or p2_os else p1_os = ap_info or p1_os p2_os = cp_info or p2_os end end end end function index() entry({"admin", "system", "advanced_reboot"}, template("advanced_reboot/advanced_reboot"), _("Advanced Reboot"), 90) entry({"admin", "system", "advanced_reboot", "reboot"}, post("action_reboot")) entry({"admin", "system", "advanced_reboot", "alternative_reboot"}, post("action_altreboot")) entry({"admin", "system", "advanced_reboot", "power_off"}, post("action_poweroff")) end function action_reboot() ltemplate.render("advanced_reboot/applyreboot", { title = i18n.translate("Rebooting..."), msg = i18n.translate("The system is rebooting now.<br /> DO NOT POWER OFF THE DEVICE!<br /> Wait a few minutes before you try to reconnect. It might be necessary to renew the address of your computer to reach the device again, depending on your settings."), addr = ip.new(type(ip) == "string" and ip or "192.168.1.1") or "192.168.1.1" }) sys.reboot() end function action_altreboot() local zyxelFlagPartition, zyxelBootFlag, zyxelNewBootFlag, errorCode, curEnvSetting, newEnvSetting errorMessage = nil errorCode = 0 if http.formvalue("cancel") then http.redirect(dispatcher.build_url('admin/system/advanced_reboot')) return end local step = tonumber(http.formvalue("step") or 1) if step == 1 then if fs.access("/usr/sbin/fw_printenv") and fs.access("/usr/sbin/fw_setenv") then ltemplate.render("advanced_reboot/alternative_reboot",{}) else ltemplate.render("advanced_reboot/advanced_reboot",{errorMessage = i18n.translate("No access to fw_printenv or fw_printenv!")}) end elseif step == 2 then if bev1 or bev2 then -- Linksys devices if bev1 then curEnvSetting = tonumber(util.trim(util.exec("fw_printenv -n " .. bev1))) if not curEnvSetting then errorMessage = errorMessage .. i18n.translate("Unable to obtain firmware environment variable") .. ": " .. bev1 .. ". " util.perror(i18n.translate("Unable to obtain firmware environment variable") .. ": " .. bev1 .. ".") else newEnvSetting = curEnvSetting == bev1p1 and bev1p2 or bev1p1 errorCode = sys.call("fw_setenv " .. bev1 .. " " .. newEnvSetting) if errorCode ~= 0 then errorMessage = errorMessage or "" .. i18n.translate("Unable to set firmware environment variable") .. ": " .. bev1 .. " " .. i18n.translate("to") .. " " .. newEnvSetting .. ". " util.perror(i18n.translate("Unable to set firmware environment variable") .. ": " .. bev1 .. " " .. i18n.translate("to") .. " " .. newEnvSetting .. ".") end end end if bev2 then curEnvSetting = util.trim(util.exec("fw_printenv -n " .. bev2)) if not curEnvSetting then errorMessage = errorMessage or "" .. i18n.translate("Unable to obtain firmware environment variable") .. ": " .. bev2 .. ". " util.perror(i18n.translate("Unable to obtain firmware environment variable") .. ": " .. bev2 .. ".") else newEnvSetting = curEnvSetting == bev2p1 and bev2p2 or bev2p1 errorCode = sys.call("fw_setenv " .. bev2 .. " '" .. newEnvSetting .. "'") if errorCode ~= 0 then errorMessage = errorMessage or "" .. i18n.translate("Unable to set firmware environment variable") .. ": " .. bev2 .. " " .. i18n.translate("to") .. " " .. newEnvSetting .. ". " util.perror(i18n.translate("Unable to set firmware environment variable") .. ": " .. bev2 .. " " .. i18n.translate("to") .. " " .. newEnvSetting .. ".") end end end else -- NetGear device if not zyxelFlagPartition then zyxelFlagPartition = util.trim(util.exec(". /lib/functions.sh; find_mtd_part 0:DUAL_FLAG")) end if not zyxelFlagPartition then errorMessage = errorMessage .. i18n.translate("Unable to find Dual Boot Flag Partition." .. " ") util.perror(i18n.translate("Unable to find Dual Boot Flag Partition.")) else zyxelBootFlag = tonumber(util.exec("dd if=" .. zyxelFlagPartition .. " bs=1 count=1 2>/dev/null | hexdump -n 1 -e '1/1 \"%d\"'")) zyxelNewBootFlag = zyxelBootFlag and zyxelBootFlag == 1 and "\\xff" or "\\x01" if zyxelNewBootFlag then errorCode = sys.call("printf \"" .. zyxelNewBootFlag .. "\" >" .. zyxelFlagPartition ) if errorCode ~= 0 then errorMessage = errorMessage or "" .. i18n.translate("Unable to set Dual Boot Flag Partition entry for partition") .. ": " .. zyxelFlagPartition .. ". " util.perror(i18n.translate("Unable to set Dual Boot Flag Partition entry for partition") .. ": " .. zyxelFlagPartition .. ".") end end end end if not errorMessage then ltemplate.render("advanced_reboot/applyreboot", { title = i18n.translate("Rebooting..."), msg = i18n.translate("The system is rebooting to an alternative partition now.<br /> DO NOT POWER OFF THE DEVICE!<br /> Wait a few minutes before you try to reconnect. It might be necessary to renew the address of your computer to reach the device again, depending on your settings."), addr = ip.new(uci:get("network", "lan", "ipaddr")) or "192.168.1.1" }) sys.reboot() else ltemplate.render("advanced_reboot/advanced_reboot",{ romBoardName=romBoardName, device_name=device_name, bev1p1=bev1p1, p1_os=p1_os, bev1p2=bev1p2, p2_os=p2_os, current_partition=current_partition, errorMessage = errorMessage}) end end end function action_poweroff() local uci = require "luci.model.uci".cursor() if http.formvalue("cancel") then http.redirect(dispatcher.build_url('admin/system/advanced_reboot')) return end local step = tonumber(http.formvalue("step") or 1) if step == 1 then if fs.access("/sbin/poweroff") then ltemplate.render("advanced_reboot/power_off",{}) else ltemplate.render("advanced_reboot/advanced_reboot",{}) end elseif step == 2 then ltemplate.render("advanced_reboot/applyreboot", { title = i18n.translate("Shutting down..."), msg = i18n.translate("The system is shutting down now.<br /> DO NOT POWER OFF THE DEVICE!<br /> It might be necessary to renew the address of your computer to reach the device again, depending on your settings."), addr = ip.new(uci:get("network", "lan", "ipaddr")) or "192.168.1.1" }) sys.call("/sbin/poweroff") end end