I've tried to get the lxc app in a more usable state. Tested with mips
and amd64 targets.
* fix missing tar/xz dependency,
only if LXC_BUSYBOX_OPTIONS is not selected
* mute needless gpg validation warning
* tidy up controller a little bit
* fix multiple possible dispatcher errors
* fix compatibility with XHTML standard theme (looks still horrible ;-)
* inform the user about custom kernel prerequisites
* inform the user about the template download
* inform the user if no template was found
Signed-off-by: Dirk Brenken <dev@brenken.org>
http.getenv("SCRIPT_NAME") fail if it's not provided. This can happen in the login screen when we don't have any script to load.
Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Do override the iface section id upon commit to avoid clobbering the resulting
configuration. The manual config sync is not needed anymore after switching
to uncached ubus uci operations.
Fixes#1770.
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
On certain environments, mainly with the embedded uhttpd interpreter, the
luci.config class cannot be loaded due to a circular dependency with the
luci.model.uci class.
Break up the dependency by deferring the loading of luci.config in
luci.model.uci until it is actually needed.
Fixes#1803, FS#1553.
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
Fixes the following error when attempting to serialize userdata objects:
.../json.lua:81: attempt to call local 'parser' (a nil value)
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
6ddea4c utils: fix crash with zero length input string in lh_header_attribute()
cb119de lib: add support for setting the maximum allowed data size
Fixes#1784.
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
A simple scan of the code indicates that currently no code in the repo
is accessing the sysauth= cookie
Closesopenwrt/luci#1555
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Signed-off-by: Yousong Zhou <yszhou4tech@gmail.com>
Change default leasefile hint from /var/log/upnp.leases to
/var/run/miniupnpd.leases
Signed-off-by: Kevin Darbyshire-Bryant <ldir@darbyshire-bryant.me.uk>
If the physical device is not set in the diag_command then the ping will
always use the route with the lowest metric from the default routing
table.
To fix this add the physical device of the logical interface to the ping
command.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If a logical interface setup and adds in the protocol handler a dynamic
interface then the gateway is configured in the dynamic interface and the
setting up logical interface does not have a gateway specified.
To fix this check first if a dynamic interface is present and use this
gateway ip if found and if no dynamich interface is set then check for a
gateway in the logical interface.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>