ipq40xx: Select correct board-2.bin for EnGenius EMD1
The board data file for the EnGenius EMD1 is not part of the default
board-2.bin which is shipped by ath10k-board-qca4019. As result, the wrong
calibration information will be loaded into the wifi chip.
Fixes: 51f3035978
("ipq40xx: add support for EnGenius EMD1")
Signed-off-by: Sven Eckelmann <sven@narfation.org>
This commit is contained in:
parent
c6a2ffd505
commit
d9f4a4280e
1 changed files with 1 additions and 0 deletions
|
@ -419,6 +419,7 @@ define Device/engenius_emd1
|
|||
IMAGES += factory.bin
|
||||
IMAGE/sysupgrade.bin := append-kernel | append-rootfs | pad-rootfs | append-metadata
|
||||
IMAGE/factory.bin := qsdk-ipq-factory-nor | check-size
|
||||
DEVICE_PACKAGES := ipq-wifi-engenius_emd1
|
||||
endef
|
||||
TARGET_DEVICES += engenius_emd1
|
||||
|
||||
|
|